INDEX20 RESEARCH · MATHEMATICAL MODEL 01
PhaseFlow 18
A reproducible experiment in hierarchical state decomposition for event-driven controllers.
MODEL
18 states as a product, not a flat list
The logical state is factored into a strategy and a processing phase:
|S| = 3 × 6 = 18
During phase t, command x(t) changes the work phase. During phase Δ, command e(Δ) selects the strategy. Both operations form one external cycle.
INTERACTIVE MODEL
Run one external cycle
The reference model is ready.
COMPARISON
Same behavior, three representations
| Implementation | Generic cells | Flip-flops | Combinational cells |
|---|---|---|---|
| Hierarchical 3 × 6 | 68 | 15 | 53 |
| Independent binary fields | 82 | 8 | 74 |
| Flat 18-state one-hot | 147 | 36 | 111 |
Generic Yosys synthesis, without a target standard-cell library. The binary version uses fewer flip-flops; the hierarchical version uses fewer generic cells in this specific controller.
WORKLOADS
Stable combinational-output transitions over 10,000 cycles
This is a switching proxy. It excludes glitches, capacitance, routing, clock-tree power and physical energy.
REPRODUCIBILITY
Evidence and method
- All 360 combinations of 18 starting states, five phase commands and four strategy commands were compared in the software reference.
- Three RTL variants were synthesized to generic gates with YoWASP Yosys 0.70.62-dev.1236.
- The exported gate networks were executed through both phases for 1,080 total cases.
- Three deterministic 10,000-cycle input profiles were used for activity comparison.
What this result does and does not establish
Established for this model
- Equivalent observable behavior over the tested state/input domain.
- 68 generic cells for the hierarchical RTL versus 82 binary and 147 flat.
- Lower stable combinational-output activity for the hierarchy in all three test profiles.
Requires further measurement
- Standard-cell area, critical timing and maximum clock rate.
- Dynamic/leakage power, physical energy and post-layout wiring.
- Advantage on a customer's real controller and workload.
QUESTIONS
Frequently asked questions
Does PhaseFlow improve Index20 website rankings?
No. This is a published research model and is not used by the production scoring engine.
Does 68 versus 82 cells prove lower silicon area?
No. Generic cells are an early synthesis result. Technology mapping, constraints, placement and routing are required for a physical area claim.
Can the method be tested on another controller?
Yes. A valid pilot needs a fixed behavior contract, the best applicable baseline, one target library and representative event traces.